Specifications

Specifications for the SATI series Ultrasonic Anemometer

Measurement Range:

Wind Velocity (V)
Wind Velocity (Vx)
Wind Velocity (Sx, K)
Wind Velocity (A)
Temperature
Wind Direction

 

±15 m/sec.
±20 m/sec.
±30 m/sec.
±65 m/sec.
-50° to +70°
0-359 degrees

Path Length:

"V" Circular Probe
"A", "Sx", "K", and "Vx" Probes

 

10 cm
15 cm

Accuracy:

Wind Speed
Orthogonality (direction)
Temperature (Absolute)
Sonic Temperature

 

±0.01 m/sec
±0.1 degrees
±1.2° C
±0.1° C or ±0.05° C

Resolution:

Wind Speed

Wind Direction
Temperature

 

0.01 m/sec. (normal)
0.001 m/sec. (optional)
0.1 degrees
0.01° C

Output:

Data Rate
Digital
BAUD Rate
Speed of Sound
Status
Raw Temperature

 

<1 Hz to 200 Hz - Variable
Serial RS-232C compatible (RS422 optional)
4800 - 460,800
Operator Optional
Operator Optional
Operator Optional

Operation

Temperature Range
Been used up to
Been used down to
Relative Humidity
Rain/Snow

 

-50° C to  +70° C
+250° C - with no damage
-80°C - with no problems
0 - 100%
Can be heated

Power Requirements: +12 VDC, @ <100 mA
(9 - 32 VDC)
Probe Array:

"A" - Non-Orthogonal
"Sx" - Single Axis
"Sx" - Two Axis
"Sx" - Three Axis
"K" - Three Axis Only
"Vx" - Three Axis Only
"V" - Three Axis Only
Weight

 

12.6cm x 22.6cm x 19.6cm
2.54cm x 15.9cm x 17.8cm
25.4cm x 25.4cm x 17.8cm
25.4cm x 35.6cm x 35.6cm
25.4cm x 33.0cm x 40.6cm
25.4cm x 25.4cm x 25.4cm
17.8cm x 17.8cm x 17.8cm
<1.0 kg

Probe Mounting (all probe styles):  3.175 cm Square Tube

 For Questions on any of these values contact
sales16@apptech.com